. Homepage | Dan the grow man | Santa Barbara, California

Gavita External Contactor Module 240 Volt Plugs

In stock
SKU
906083
$89.50
Size Chart
Quick Overview
Gavita External Contactor Module 240 Volt Plugs

Secured and trusted checkout with

Gavita External Contactor Module ECM1

Lighting control at your fingertips

External Contactor Module (15A) with blue indication LED follows lights-on for main channel. Use ECMs to switch CO2, fertigation, heating etc. during lights-on or lights-off cycle. ECMs can be positioned close to the actual accessories. Cable outputs with female and male connector allow easy connection of accessories. Contains industrial contactor, suitable to power 15A loads or to power trigger input. Cage clamp connection for control cord allows easy installation.

The controller can switch all the interconnected fixtures on and off with its internal timer, adjust them to your required output level (in percentage or exact output power) and even simulate sunrise and sunset to gradually adjust the climate in your grow room when your lights go on or off. This electronic controller replaces expensive lighting timers and contactors while preventing ballast current in-rush when switching on your lights.

Two very important features are the autodim function and emergency shut-down. When the temperature in your grow room rises beyond the control level of your climate control your crop can be damaged beyond recovery. The temperature probe senses this and will automatically dim the lights to not overshoot your safe temperature, and maintain it. The display and warning LED indicate when this happens, and also indicate if this has happened while you were away so you can correct the problem. If for any reason your climate control completely fails and the temperature rises to unacceptable levels the system will perform an emergency shutdown of all connected equipment. The alarm contact of the controller can be connected to your alarm system for instant notification.
You can connect all your e-series fixtures to one controller.

Features & Benefits

  • plug playNo need for a switchboard
  • No high inrushes (ballast is always stand-by)
  • Easy and safe installation (low voltage device)
  • Protected against shortcuts
  • Double temperature safety feature (autodim/auto shutdown)
  • For 40 ballasts
  • For DigiStar and Pro-lines e-series, incl. LEP
  • Sunrise/sunset built in (0-30 mins)
  • Show output in % or Watts
  • Celsius or Fahrenheit and 24 hr/AM/PM
  • Calibrate temperature sensors
  • CE-logo 75pxcertified

 

Specifications

  • 24 hour timer (on/off):Yes
  • Set output level:50-115%
  • Select ballast type:400/600/750/1000W
  • Show output as W or %:Yes
  • Auto-dim at set temp:Yes
  • Auto shutdown at set temp:Yes
  • Sunrise / sunset period:Yes
  • Outputs:1 (main)
  • Number of ballasts per output:40
  • Total number of ballasts:40
  • Temperature sensors:1 (main)
  • Alarm contacts NO/NC:-
  • External Contactor Modules (ECM):-
  • Warrenty:3 years
  • Article Number:60.55.00.23.10 (EU) | 60.55.00.24.11 (UK) | 60.55.00.12.20 (US) | 60.55.00.24.60 (AU)
  • EAN code:8718403051735 (EU) | 8718403051759 (UK) | 8718403051773 (US) | 8718403051797 (AU)

     